HOME > Lineup of Charging/Discharge test device
 

Lineup of Large current charging/discharge test device (G-Version: 1s/2ms for high-speed sampling)

Lineup of Small current charging/discharge test device (G-Version: 1s/2ms for high-speed sampling)
Note: CH count → CH count per unit
Click on the model number to see a picture (external view) of the product.
Unit Model CH Voltage setting range
(Accuracy F.S.)
Voltage measuring ranges
(Accuracy F.S.)
Current setting range
(Accuracy F.S.)
Current measurement range
With auto range
(Accuracy F.S.)
Temperature measurement Normal Charging and discharging Pulse Charging and discharging
ACD-R1APS(1L)-05N 4 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.2%)
Large range ±100mA
(±0.1%)
1/1 ±100mA
(±0.1%)
CC-CV
CC
CP
CR
CC
CP
PWM
Burst
1/5 ±20mA
(±0.4%)
1/20 ±5mA
(±0.4%)
Small range ±1mA
(±0.1%)
1/1 ±1000µA
(±0.1%)
Burst
1/5 ±200µA
(±0.4%)
1/20 ±50µA
(±0.5%)
ACD-01APS-05N 4 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.1%)
Large range ±1A
(±0.1%)
1/1 ±1A
(±0.1%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/5 ±0.2A
(±0.4%)
1/20 ±0.05A
(±0.4%)
Small range ±0.1A
(±0.1%)
1/1 ±100mA
(±0.1%)
Burst
1/5 ±20mA
(±0.4%)
1/20 ±5mA
(±0.5%)
ACD-06APS(R1)-05N 4 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.2%)
Large range ±6A
(±0.1%)
1/1 ±6A
(±0.2%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/5 ±1.2A
(±0.2%)
1/20 ±0.3A
(±0.4%)
Small range ±0.1A
(±0.1%)
1/1 ±100mA
(±0.1%)
Burst
1/5 ±20mA
(±0.4%)
1/20 ±5mA
(±0.5%)
ACD-10APS(01)-05N 4 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.2%)
Large range ±10A
(±0.1%)
1/1 ±10A
(±0.2%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/5 ±2A
(±0.2%)
1/20 ±0.5A
(±0.4%)
Small range ±1A
(±0.1%)
1/1 ±1A
(±0.2%)
1/5 ±0.2A
(±0.2%)
1/20 ±0.05A
(±0.4%)
ACD-20APS(02)-05N 2 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.2%)
Large range ±20A
(±0.1%)
1/1 ±20A
(±0.2%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/5 ±4A
(±0.2%)
1/20 ±1A
(±0.4%)
Small range ±2A
(±0.1%)
1/1 ±2A
(±0.2%)
1/5 ±0.4A
(±0.2%)
1/20 ±0.1A
(±0.2%)
ACD-20APP-25N
(仮想パック対応)
1 Charge
1~+25V
(±0.2%) Discharge
1~+25V
(±0.4%)
0~+25V
(±0.2%)
Large range ±20A
(±0.2%)
1/1 ±20A
(±0.2%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/5 ±4A
(±0.4%)
1/20 ±1A
(±0.4%)
Small range ±10A
(±0.2%)
1/1 ±10A
(±0.2%)
1/5 ±2A
(±0.4%)
1/20 ±0.5A
(±0.4%)
ACD-50APS-05N 1 Charge
0~+5V
(±0.1%) Discharge
0~+5V
(±0.2%)
-1~+5V
(±0.2%)
Large range ±50A
(±0.2%)
1/1 ±50A
(±0.2%)
CC-CV
CC
CP
CR
CC
CP
CR
PWM
Burst
1/10 ±5A
(±0.4%)
Small range ±5A
(±0.2%)
1/1 ±5A
(±0.2%)
1/10 ±0.5A
(±0.4%)
ACD-100APS-05N 1 0~+5V
(±0.4%)
0~+5V
(±0.4%)
Large range ±100A
(±0.4%)
1/1 ±100A
(±0.4%)
CC-CV
CC
CP
CR
(CC-CV
Except for the discharge)
Burst
ACD-150APS-05N 1 0~+5V
(±0.4%)
0~+5V
(±0.2%)
Large range ±150A
(±0.4%)
1/1 ±150A
(±0.4%)
ACD-200APS-05N 1 0~+5V
(±0.4%)
0~+5V
(±0.2%)
Large range ±200A
(±0.4%)
1/1 ±200A
(±0.4%)
  • CV charging cannot be performed in cases where battery voltage is higher than the configured voltage at times of CC-CV charging. Similarly, CV discharge cannot be performed in cases where battery voltage is lower than the configured voltage at times of CC-CV discharge. At such times, the current measures during charging and discharge is a few µA, but the current actually flowing to the battery is no more than 1 µA (almost an open state).
  • Do not conduct tests where the measuring current is “less than 1% of the configured current range FS.”
  • The above degree of certainty is that during normal charging and discharge. Since the degree of certainty differs according to the charging and discharge mode, see the individual unit specifications for details.

 

 
Close
Top of page